■NECKEASE NEK TRACTION
Brief Introduction
As a new type of health care product, "Sheng Chen" brand Neckease (Necktraction Fixer) was designed and developed for the prevention and treatment of cervical vertebral disease. Based on the Air-traction Magnetic-cure principal, Neckease can effectively aid the treatment of cervical disease, improve the blood supply to neck and brain, release many kinds of symptoms caused by cervical disease. Neckease has curative effect on cervical alterations, protrusion of inter-vertebral disc, slenosis of the vertebral channel, injuries and osteomilagic carelessness, as well as the hemiparesis due to cervical vertebral pathology. The patients can conduct self-treatment anytime at any places and need not visit the doctor frequently.
Characteristic of Use
1. Speed of result: It proves effective within short time.
2. Efficiency and duration: the symptoms obviously diminish or disappear after continuous applications for several weeks.
3. Convenience: It is portable and has adjustable traction angle and force.
4. Safety: The product causes no pain and side effects if used in accordance with the instruction given.
Function Characteristic
Made up of inner latex chamber and new type of soft textile covering. Neckease is small and light (250g), powerful (0-100kg) with a wide traction range (1-20cm). It has a special dynamic structure that can automatically protect the specific area of the cervical tract after it has been inflated and modeled. The low and high pressure air chambers can improve the patient's comfort durin traction and immobilization. Magnets can enhance the treatment effect.
How to Use See figure I below
1 Put Neckease around neck, adjust the circle for different sizes and fix the nylon strap in the front. First users may wear it with a mirror. Please note that the air inlet ball should be placed in the side of left hand.
■ A Detail of the ball valve for blocking the airflow
■ A1 Open
■ A2 Closed
■ B Detail of the valve for deflation
■ B1 Turn for deflation
■ B2 Turn for air inlet
2 Fasten the air-releasing screw before hand-pumping. Make sure the direction of the rubber cushion is correct. See figure2 below
■ 1 Low-pressure air chamber
■2 High-pressure air chamber
■3 Valve for air passage under low pressure
■4 Four-cross connector
■5 Blocking ball valve
■6 Valve for deflation
■7 Valve cushion
■8 Air inlet ball
■9 Nylon strap
■10 Magnet
Figure 2
3 Pump with hand till symptoms subside. Making sure it comes to an optimal pressure, close the ball valve.
4 The fixing control should be used at lest 2-3 times a day with a minimum of 30 minutes each time.
5 Open the ball valve and loosen the air-releasing screw after use and let the air out slowly.
Instrument
Carry out the following steps:
Inflate the appliance to obtain medium traction for a few minutes, deflate, and reinflate at medium traction for a few more minutes before finishing the treatment. According to the situation, re-inflate to within the resistance limit to increase the beneficial effects, carry out greater traction for several minutes and adjust the traction angle. Generally, one circle of treatment is 30 days. Frequently use of Neckease is beneficial to health.
Pathology of cervical spondylopathy and principle of traction treatment
The reason of cervical spondylopthy is degeneration of cervical inter-vertebral disc. Septum turning to narrow, local tissue swelling, stasis of blood, compression of vas, and then a series of symptoms happen. Effective traction could get rid of compression of nervous vas, therefore, diminish the symptoms; repeated traction could get muscles of neck relax, local tissue swelling and stasis of blood disappear. So the symptoms of cervical spondylopathy soon remit or disappear completely.
Recommendation
1 The patients should relax as much as possible during the treatment.
2 You must be an abnormal reaction during the treatment, the air should be let out slowly, and the angulation and the level of traction should be regulated till the situation normalizes and then the traction should be retreated.
3 When using the medium or high traction, the low-pressure air-chamber on the top should be closed before the inflation process is finished. In this way the upper parts of the air-chamber remains soft and comfortable during treatment.
4 Traction at high level should only be carried out after the application of 30-60 minutes at low and medium level. Repositioning the angulation of traction must be carried out following medical advice.
5 Hard ,sharp objects do not come into contact with Neskease during use. If the surface is dirty, it should be cleaned delicately with a brush, but it should not be rubbed and washed.
|
|
|
|